Le nkqubo yomoya omtsha eme nkqo iyilwe ngokukhethekileyo ngoyilo oluneendlela ezimbini zokuqinisekisa ukujikeleza komoya ngaphakathi.I-hexagonal iyonke yokutshintsha ubushushu ingundoqo inokutshintshiselana ngokufanelekileyo ubushushu kunye nokufuma ukuphucula intuthuzelo yangaphakathi.Inkqubo ikwaxhotyiswe ngomsebenzi wokucoca we-HEPA ohluza kwaye uhlambulule umoya wangaphakathi kwaye ususa zonke iintlobo zezinto ezinobungozi, ukuvumela ukuba uphefumle ngokusempilweni.
Ukongeza, umsebenzi wohlengahlengiso lwesantya ezine ikuvumela ukuba ulungelelanise umthamo womoya ngokweemfuno zakho, ukuzisa indawo ekhululekile yangaphakathi.
Ukuhamba komoya: 250 ~ 500m³ ukuhamba komoya
Umzekelo: TFPW C1 series
Iimpawu:
• Ukufudumeza kwangaphambili umoya wokungena ngaphandle, ukukhusela i-enthalpy exchange core ekukhenkceni
• Ukungenisa umoya wokubuyisela amandla (ERV)
• Ukusebenza ngokucokisekileyo ukuya kuma-99%
• Ukusebenza kakuhle kokubuyisela ubushushu ukuya kuthi ga kwi-93%
• Imowudi ye-Smart defrost
• Ukubonelela ngonxibelelwano lwe-RS485
• Umsebenzi wokugqitha
• Ubushushu bokusebenza kwindawo: (-25℃~43℃)
• Isihluzo sokuvala inzala ye-IFD (uyazikhethela)
I-villa
Isakhiwo sokuhlala
Ihotele / iApartment
Isakhiwo soRhwebo
Umzekelo | Ukuhamba komoya okukalwe(m³/h) | Ikalwe nge-ESP(Pa) | Temp.Eff(%) | Ingxolo(dB(A)) | I-Vlot.(V/Hz) | Amandla (igalelo)(W) | NW(Kg) | Ubungakanani(mm) | Ubungakanani bokudibanisa(mm) | |
TFPW-025(C1-1D2) | 250 | 100(200) | 80-93 | 34 | 210-240/50 | 90+(300) W | 50 | 850*400*750 | φ150 | |
TFPW-035(C1-1D2) | 350 | 100(200) | 75-90 | 36 | 210-240/50 | 140+(300) W | 55 | 850*400*750 | φ150 | |
TFPW-045(C1-1D2) | 450 | 100(200) | 73-88 | 42 | 210-240/50 | 200+(300) W | 65 | 850*400*750 | Φ200 |
Le ERV ethe nkqo ifanelekile kwiyunithi yendlu enentloko engonelanga
• Inkqubo isebenzisa ubuchwepheshe bokubuyisela amandla omoya.
• Idibanisa ukungena komoya okulungelelanisiweyo, ukufudumeza umoya omtsha ebusika.
• Inika umoya omtsha osempilweni kunye nokhululekileyo ngelixa ugcina amandla aphezulu, ukusebenza kakuhle kokubuyisela ubushushu ukuya kuma-90%.
• Gcina izithuba zeemodyuli zomsebenzi oqhelekileyo.
• Umsebenzi wokugqitha usemgangathweni.
• Ukufudumala kwe-PTC, qinisekisa ukusebenza kwindawo yobushushu obuphantsi ebusika
Isitshintshi sobushushu esihlambekayo se-enthalpy
1. Ukusebenza okuphezulu kwe-cross-counterflow enthalpy heat exchanger
2. Kulula ukuyigcina
3. 5 ~ 10 iminyaka ubomi
4. Ukuya kuthi ga kwi-93% yokutshintsha kobushushu obusebenzayo
Uphawu Oluphambili:Ukusebenza kokubuyiswa kobushushu kufikelela kwi-85% Ukuphumelela kwe-Enthalpy ukuya kuthi ga kwi-76% Iqondo lotshintshiselwano lomoya olusebenzayo ngaphezu kwe-98% ekhethiweyo ye-molecular osmosis I-flame retardant, i-antibacterial kunye nokumelana nokungunda.
Umgaqo wokusebenza:Iipleyiti ezisicaba kunye neepleyiti ezinamazinki zenza imijelo yokufunxa okanye yokukhupha umoya.Amandla afunyanwa kwakhona xa imiphunga yomoya emibini idlula kwi-exchanger ngokunqamleza kunye nomahluko wobushushu.
Ulawulo oluBukrelekrele: I-APP yeTuya ngokubambisana nomlawuli okrelekrele inika uluhlu lwemisebenzi elungiselelwe iimfuno zeprojekthi ezahlukeneyo.
Umboniso wobushushu uvumela ukujonga rhoqo amaqondo obushushu angaphakathi nangaphandle.
Umbane wokuziqalela ngokutsha umsebenzi uqinisekisa ukuba inkqubo ye-ERV ifumana kwakhona ngokuzenzekelayo ekucinyweni kombane.
Ulawulo loxinaniso lwe-CO2 lugcina umgangatho womoya ophezulu.Inzwa yokufuma ilawula amanqanaba okufuma angaphakathi.
Iziqhagamshelo ze-RS485 ziququzelela ulawulo oluphakathi nge-BMS.Ulawulo lwangaphandle kunye / nesiphumo sophawu lwempazamo lwenza abalawuli balawule kwaye balawule i-ventilator ngaphandle komzamo.
Inkqubo ye-alam yokucoca ilumkisa abasebenzisi ukuba bacoce isihluzo ngexesha elifanelekileyo.